UV222 Linear

UV222 LINEAR

Minimise the risk of surgical site infections

Designed for operating theatres, this lamp upholds cleanliness standards crucial for sterile environments by reducing microbial load, thereby lowering the risk of surgical site infections and improving patient safety and outcomes.

Category: Tags: ,

Description

As a linear light for operating theatres, the UV222 Linear seamlessly integrates visible light and continuous air and surface decontamination. It is designed for installation in operating theatres and various settings requiring the dual effect of visible and Far-UVC light at 222 nm, such as patient rooms, restrooms, medical staff rooms, and waiting areas.

In operating theatres, the UV222 Linear offers flexibility, suitable for installation as a stand-alone unit or integrated with a Laminar Air Flow (LAF) system. This integration ensures effective, chemical-free decontamination, serving as a powerful asset in maintaining the cleanliness and safety standards of modern surgical facilities — all without posing any risk to patients or medical staff.

UV222 Linear is available as both a 60° and 100° version, and every lamp is measured after production and sent with its unique specifications report. The spatial and spectral distribution of the light is measured on each lamp using a 2-axis goniometer, giving the entire 3D distribution of the Far UV-C light emitted by it.

 

True and flicker-free colours

The UV222 Linear combines decontamination and strong lighting, providing clear, true colours with a 90 CRI and 4,000 K. Its flicker-free design and colour variation help reduce fatigue and boost productivity for surgeons and nurses.

Far UVC lamp certification logos

 

Light measurement results

60° beam angle 100° beam angle
126.92 mW Output – total optical power flux, 200 nm – 850 nm 75.72 mW
120.79 mW Far UV-C 200 nm – 230 nm 58.79 mW
6.81 mW VIS-IR: 400 nm – 850 nm 10.71 mW
0.926 % Radiated power/lamp power 0.57 %
222 nm Peak emission wavelength 222 nm
13.8 μW/cm2 UV (222 nm) irradiance at centre at 1 m (3’ 10”) 3.2 μW/cm2
60° Beam angle 100°

 

Specifications

Light source Krypton chloride excimer lamp / white light / RGB
Wave length 222 nm
Output 115 mW (Typical)
Input voltage 80-264 V AC
Max power consumption 60 W
Mode Continuous / duty cycle / motion activated
Weight 2.3 kg (5.07 lbs)
Dimensions† 999 x 60 x 59 mm (39.33 x 2.36 x 2.32 in)
Power/data lead 3 x 0.5 mm² (20 AWG) + 1 pair twisted data
Operating temperature 0° to +40° C (32° to 104° F)

 

 

 

Title