Description
Designed to minimise environmental bioburden
Cleanrooms are spaces with a controlled level of contamination. They are designed to control and limit microbiological contamination when it represents a risk to product quality, patients or consumers. Cleanrooms are necessary in many industries, from the automotive industry to pharmaceuticals, and are subject to strict monitoring of pollutants in air and on surfaces.
The UV222 Booth can help to meet the established limits for microbial contamination by disinfecting gowned personnel right at the entrance of high-grade classified areas.
Using filtered Far-UVC, which is safe for use in occupied spaces, the UV222 Booth offers operator disinfection in under 30 seconds and an advanced touchless operation interface with built-in safety parameters. The UV222 Booth is a revolutionary addition to current contamination control measures in cleanrooms. It eliminates any residual microorganisms present on protective equipment*, ensuring a higher grade of cleanliness and a lower risk of product contamination.
The UV222 Booth can be delivered as a stand-alone solution or as a customised version, encased in a stainless steel frame from floor to ceiling to fully integrate in any cleanroom.
Comply with Annex 1 using the groundbreaking UV222 Booth
The new Annex 1, which took effect on 25 August 2023, mandates that manufacturers of sterile products must implement measures to minimise the risk of microbial contamination.
The UV222 Booth aids compliance with Annex 1 by effectively inactivating microorganisms on gowned personnel before they enter high-grade cleanroom areas.

Specifications
| Light source |
Krypton chloride excimer lamp |
| Wavelength |
222 nm |
| Dose in 30 sec. (at centre) |
12.0 mJ/cm²† |
| Input voltage |
230 V AC (50/60 Hz) |
| Mode |
30 sec. duty cycle† |
| Max power consumption |
3 kW |
| Weight |
430 kg (948 lbs)† |
| Dimensions† |
L: 1,250 mm
W: min 1,453 mm
H: 2,170 mm(49.21 x 57.20 x 85.43 in)† |
| Operating temperature |
0° to + 50°C (32° to 122°F) |
| Ambient humidity |
5–90% RH |
Efficacy
| Microorganism |
Type |
Time for decontamination (sec.)‡ |
Reduction in 30 sec. (%)‡ |
| Escherichia coli |
Bacteria |
4.78 |
>99,9 % |
| Listeria monocytogenes |
Bacteria |
8.15 |
>99,9 % |
| Salmonella Typhimurium |
Bacteria |
4.49 |
>99,9 % |
| Staphylococcus aureus |
Bacteria |
7.38 |
>99,9 % |
| Candida albicans |
Fungi |
22.37 |
95.4% |
| Bacillus subtilis spores |
Spores |
14.44 |
99.2% |
| Influenza virus |
Virus |
2.92 |
>99,9 % |
| SARS-CoV-2 |
Virus |
2.73 |
>99,9 % |